How our calculators work

This page is the contract for every number on this hub: the exact formulae, where they come from, how results are rounded, and what the tools deliberately refuse to claim.

The definitions everything rests on

Power is the rate of energy transfer, measured in watts (joules per second); electrical energy used over time is measured in watt-hours and kilowatt-hours; one ampere-hour is 3,600 coulombs of charge. These are the international SI definitions maintained by the BIPM and applied in the NIST Guide to the SI (SP 811), Appendix B.8. For the plain-language version — capacity in watts and kilowatts, consumption in kilowatt-hours — see the U.S. Energy Information Administration, Measuring electricity. All sources were accessed and verified on 15 November 2026.

Unit converter

Three identities, applied to unrounded internal values: watt-hours = amp-hours × volts; amp-hours = watt-hours ÷ volts; kilowatt-hours = watt-hours ÷ 1,000. Watt-hours and kilowatt-hours convert without a voltage; amp-hours are withheld until a positive nominal voltage is supplied, because amp-hours alone do not state energy. Displayed watt-hours and amp-hours carry two decimal places, kilowatt-hours three, with trailing zeros trimmed.

Appliance running cost

Daily energy (kWh) = (watts ÷ 1,000) × hours per day × duty fraction, where the duty fraction is the share of time the appliance actually draws its running watts. Cost per day multiplies that energy by a price per kWh that only the reader can supply from their own bill; period and annual figures scale the daily cost by the chosen days and by 365. The tool ships with no tariff, substitutes no "average" price, and shows energy alone when the price field is blank. Zero hours, zero duty and a zero tariff are accepted as meaningful answers.

Battery runtime — one energy boundary

Runtime estimates fail quietly when losses are counted twice or in the wrong place, so this calculator defines a single boundary and states it. Usable battery energy E is the nameplate watt-hours multiplied by a usable fraction the reader supplies — or, when the reader enters already-usable watt-hours, that figure exactly, with no second reduction. Average AC load L is the sum over loads of running watts × duty fraction. Battery-side draw B = L ÷ inverter efficiency + separately accounted battery-side DC idle watts. Runtime = E ÷ B.

Three consequences follow. Efficiency is applied once, to the load side — never again to E. Idle draw is added on the battery side only when the reader says their efficiency figure excludes standby overhead; the alternative is shown and chosen explicitly to prevent double counting. And efficiency is treated as constant, with that simplification disclosed, because part-load efficiency curves are model-specific data this hub does not have and will not invent. Background on what inverters do: U.S. Department of Energy, Solar Integration: Inverters and Grid Services Basics.

Inputs, errors and rounding

Non-numeric, infinite or negative values produce a plain-text error and no result — never a silent clamp, a guessed default, or an "Infinity" runtime. Capacity, voltage, efficiency and usable fraction must be positive; a runtime needs a positive total load. Runtime is shown to one decimal place (with hours and minutes added under two hours); displayed precision is presentation, not a claim that the underlying estimate is that accurate. Test vectors prove the arithmetic only, never real-system performance.

What these tools do not claim

They estimate energy, duration and cost from reader-supplied label values. They do not certify that any appliance will start or run safely on any battery: startup surges, continuous ratings and protection behaviour are model-specific and belong to manufacturers' manuals. They contain no mains-wiring guidance, no prices, no product offers, no ratings and no laboratory or test claims. Real outcomes vary with temperature, battery age, charge state and actual duty cycles.

Privacy and updates

All calculation is client-local in the reader's browser. Inputs are not transmitted, stored or logged, and these pages add no analytics. Pages carry a last-reviewed date; when a cited source moves or a formula needs correction, the change is made here first and the date updated.