Insulation sold in North America is usually labelled with a US R-value, while European data sheets use SI resistance (RSI) or a U-value. They describe the same resistance in different units. Enter the number from your label, say which unit it is in, and this worksheet shows all three — because a bare “R” on its own is ambiguous.

Value from your label or data sheet

Worked example

A batt labelled R-20 (US): RSI = 20 × 0.1761101838 = 3.5222 m²·K/W, and U = 1 ÷ 3.5222 = 0.2839 W/m²·K. Working the other way, a European U-value of 0.30 W/m²·K is RSI 1 ÷ 0.30 = 3.3333 m²·K/W, which is 3.3333 ÷ 0.1761101838 ≈ R-18.93 (US). An RSI of 5 is U 0.20 and about R-28.39 (US).

Method

One US/Imperial R unit (1 h·ft²·°F/Btu) equals 0.1761101838 m²·K/W of SI resistance, the unrounded dimensional factor from the foot, hour, Fahrenheit-degree interval and the International Table Btu. Government guides round the same relationship to RSI = R ÷ 5.678. The SI U-value is the reciprocal of resistance: U = 1 ÷ RSI. This converter calculates unrounded and trims only for display, so converting there and back returns your starting number within display rounding.

Limits

  • This converts units only. It does not work out the U-value of a whole wall, roof, floor or window from a product R-value: a real assembly includes other layers, framing, air films and fixings.
  • Never add U-values of layers together. Where layer resistances in series are added at all, it is the RSI (or US R) values that add, and only for the defined scope of that calculation.
  • A label R-value is the maker’s figure for that product under its test conditions. This page gives no compliance check, no minimum specification and no retrofit recommendation.
  • Canadian labels commonly print both RSI and R; if yours does, the two printed numbers should match this conversion within their rounding.

Sources

Last reviewed 16 November 2026. Calculations stay local: they happen in your browser, and nothing you enter is sent or stored.