Skip to main content
Tradvolt

Solar battery charging time calculator

Enter your battery size, the charge you have and want, and what your panel is actually delivering. This worksheet returns the hours needed if that effective output stayed constant. It is an arithmetic check on your own readings — not a weather forecast, and it assumes nothing about where you live.

Calculations stay local in your browser. Nothing you enter is sent or stored. Last reviewed 16 November 2026.

1 · Battery

Example assumption: 1,000 Wh. Replace it with your label figure.

2 · Panel and charging

Method

Energy to add = capacity (Wh) × (target % − current %) ÷ 100. Net charging power = panel rated watts × effective output fraction × charge efficiency − DC running load. Hours at the entered constant effective output = energy to add ÷ net charging power. The result counts only hours during which output really held at the level you entered. It is not elapsed calendar time: an evening, a cloudy spell or a winter day stretches the clock without changing this sum. If the target equals the current charge, the answer is 0 hours; if the net power is zero or negative while energy is still needed, the page says it cannot charge under those inputs instead of showing an infinite time.

Worked example (the pre-filled numbers)

Example assumptions, chosen for arithmetic only — not typical values for any place or product: a 1,000 Wh battery going from 20% to 80% needs 1,000 × 0.60 = 600 Wh. A 200 W panel at 75% effective output and 90% charge efficiency gives 200 × 0.75 × 0.90 = 135 W; minus a 20 W DC load leaves 115 W net. Time = 600 ÷ 115 ≈ 5.22 hours at that constant output (about 5 h 13 min of equivalent full-output charging). Second check: 2,048 Wh from 0% to 100% with a 400 W panel at 80% effective, 90% efficiency and no DC load gives 2,048 ÷ 288 ≈ 7.11 hours.

Limitations

  • Real panel output moves minute to minute with sun angle, cloud, temperature, snow, shading and panel orientation. A single effective-output figure is a snapshot, so re-read it and re-run the sum as conditions change.
  • Charging usually slows near full (charge taper), and controllers may limit input below the panel rating. The last part of a charge often takes longer than this straight-line estimate.
  • Nameplate capacity is not necessarily the energy you can cycle between two displayed percentages; battery management reserves, age and temperature all change it. Your manual's usable-capacity figure, when given, is the better input.
  • This page gives no panel, battery or mains wiring guidance and sizes nothing. Follow your equipment manuals, and use a qualified electrician for fixed wiring.

Sources

Electrical units (watt, watt-hour as power × time) follow the BIPM SI definitions and the NIST Guide to the SI, Appendix B.8; plain-language unit guidance: U.S. Energy Information Administration, Measuring electricity. Context that photovoltaic system output depends on sunlight, orientation and system losses: U.S. Department of Energy, Solar Photovoltaic System Design Basics. No source on this page supplies a default sun-hour, yield or efficiency figure for your location — those numbers must come from your own readings.

Keep going